Line 88: | Line 88: | ||
* Next, set up for an intermiary solution. | * Next, set up for an intermiary solution. | ||
* Press ''L'', ''+'' and ''7'' to set the solution type to ''G-Gxs combination''. | * Press ''L'', ''+'' and ''7'' to set the solution type to ''G-Gxs combination''. | ||
- | * Press ''''' and ''3'' to change the suppression method to SUPMET__COMB1. | + | * Press ''''' and ''3'' to change the suppression method to %%SUPMET__COMB1%%. |
* Press ''-'', ''A'', ''1'', ''2'' (press enter), ''2'', ''5'' (press enter), ''3'' and ''4'' (press enter) to set up the singularity check with the recommended parameters. Press ''S'' to save & return. | * Press ''-'', ''A'', ''1'', ''2'' (press enter), ''2'', ''5'' (press enter), ''3'' and ''4'' (press enter) to set up the singularity check with the recommended parameters. Press ''S'' to save & return. | ||
* Enter the sites menu with ''E'' and toggle mode to Automatic with ''*''. Press ''C'' and set the time interval to 300 minutes (''300'' ), polynomial order to 2 (''2''), and use Batch mode (''B''). Set the reference station as before. | * Enter the sites menu with ''E'' and toggle mode to Automatic with ''*''. Press ''C'' and set the time interval to 300 minutes (''300'' ), polynomial order to 2 (''2''), and use Batch mode (''B''). Set the reference station as before. | ||
Line 121: | Line 121: | ||
(W) Weights update (H) On-line help | (W) Weights update (H) On-line help | ||
</code> | </code> | ||
+ | |||
* Press ''P'' to proceed with detection & elimination & press ''S'' to save the results & generate a new solution. If the wrms is between 15 and 100 psec with the ''used observations'' precetage > 80%, then it's regarded as good. Significantly worse wrms/low acceptance suggests mishanded clock breaks, un- or mis-applied calibration, or maybe a bad station. | * Press ''P'' to proceed with detection & elimination & press ''S'' to save the results & generate a new solution. If the wrms is between 15 and 100 psec with the ''used observations'' precetage > 80%, then it's regarded as good. Significantly worse wrms/low acceptance suggests mishanded clock breaks, un- or mis-applied calibration, or maybe a bad station. | ||
* Assuming that you have a good solution, or one with known and uncorrectable problems, you can then go on to generate a final solution. | * Assuming that you have a good solution, or one with known and uncorrectable problems, you can then go on to generate a final solution. |