User Tools

Site Tools


analysis:solve

This wiki is not maintained! Do not use this when setting up AuScope experiments!

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
analysis:solve [2014/08/12 03:21]
Jamie McCallum
analysis:solve [2014/08/12 03:37]
Jamie McCallum [Start calc/solve & get a viable solution]
Line 88: Line 88:
   * Next, set up for an intermiary solution. ​   * Next, set up for an intermiary solution. ​
     * Press ''​L'',​ ''​+''​ and ''​7''​ to set the solution type to ''​G-Gxs combination''​. ​     * Press ''​L'',​ ''​+''​ and ''​7''​ to set the solution type to ''​G-Gxs combination''​. ​
-    * Press '''''​ and ''​3''​ to change the suppression method to SUPMET__COMB1.+    * Press '''''​ and ''​3''​ to change the suppression method to %%SUPMET__COMB1%%.
     * Press ''​-'',​ ''​A'',​ ''​1'',​ ''​2''​ (press enter), ''​2'',​ ''​5''​ (press enter), ''​3''​ and ''​4''​ (press enter) to set up the singularity check with the recommended parameters. Press ''​S''​ to save & return.     * Press ''​-'',​ ''​A'',​ ''​1'',​ ''​2''​ (press enter), ''​2'',​ ''​5''​ (press enter), ''​3''​ and ''​4''​ (press enter) to set up the singularity check with the recommended parameters. Press ''​S''​ to save & return.
     * Enter the sites menu with ''​E''​ and toggle mode to Automatic with ''​*''​. Press ''​C''​ and set the time interval to 300 minutes (''​300''​ ), polynomial order to 2 (''​2''​),​ and use Batch mode (''​B''​). Set the reference station as before.     * Enter the sites menu with ''​E''​ and toggle mode to Automatic with ''​*''​. Press ''​C''​ and set the time interval to 300 minutes (''​300''​ ), polynomial order to 2 (''​2''​),​ and use Batch mode (''​B''​). Set the reference station as before.
Line 121: Line 121:
 (W) Weights update ​                        (H) On-line help (W) Weights update ​                        (H) On-line help
 </​code>​ </​code>​
 +
   * Press ''​P''​ to proceed with detection & elimination & press ''​S''​ to save the results & generate a new  solution. If the wrms is between 15 and 100 psec with the ''​used observations''​ precetage > 80%, then it's regarded as good. Significantly worse wrms/low acceptance suggests mishanded clock breaks, un- or mis-applied calibration,​ or maybe a bad station.   * Press ''​P''​ to proceed with detection & elimination & press ''​S''​ to save the results & generate a new  solution. If the wrms is between 15 and 100 psec with the ''​used observations''​ precetage > 80%, then it's regarded as good. Significantly worse wrms/low acceptance suggests mishanded clock breaks, un- or mis-applied calibration,​ or maybe a bad station.
   * Assuming that you have a good solution, or one with known and uncorrectable problems, you can then go on to generate a final solution.   * Assuming that you have a good solution, or one with known and uncorrectable problems, you can then go on to generate a final solution.
/home/www/auscope/opswiki/data/pages/analysis/solve.txt · Last modified: 2014/08/12 04:09 by Jamie McCallum