This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
handover:aov003 [2015/05/17 01:50] cjordan |
handover:aov003 [2015/05/17 10:00] cjordan |
||
---|---|---|---|
Line 6: | Line 6: | ||
Data volume at beginning: 6529 GB | Data volume at beginning: 6529 GB | ||
+ | |||
+ | * 10:00 UT - Steep slopes on several channels in the autocorrelation spectrum (vk) | ||
**Hobart 26m:** | **Hobart 26m:** | ||
Line 13: | Line 15: | ||
Data volume at beginning: 11844 GB | Data volume at beginning: 11844 GB | ||
- | * 01:35 UT - system temperatures are much too high (>1000); attenuation is probably not set right. | + | * System temperatures are much too high (>1000). Liza has been working hard, but no solution has been found to this problem. Intermittent halting of schedule occurs between 01:30 and 02:00. Additionally, a formatter time offset became apparent and was fixed between these time ranges (Chris) |
+ | * 04:10: The "calu -m pcfs" command makes things a lot more sensible. Unsure of the data quality before this time. (Chris) | ||
**Katherine 12m:** | **Katherine 12m:** | ||
Line 40: | Line 43: | ||
* Schedule starts late, because atsnap was not run with schedule= (Chris) | * Schedule starts late, because atsnap was not run with schedule= (Chris) | ||
* Starts after 00:10 UT | * Starts after 00:10 UT | ||
- | * Scan - missed | + | * Corresponding scans before this time are presumably missed. |