 Data volume at beginning: 6.090 GB Data volume at beginning: 6.090 GB
  
-  * During setup, ke dbbc needed a power cycle, This fixed the issue of drifting time difference ​and bad auto correl spectra. (AK)+  * 17:30 Experiment started okay (Liz) 
 +  * 17:35 UT Alarm "mark 5 reports sync error. Check clock stability."​ which developed into "​dbbcn:​error connect():dbbc device connection open timed-out"​. Had to halt schedule, ​power cycle the DBBC and fmset to fixFirst good scan 264-1815 ​(Liz) 
 +  * 18:25 UT Autocorrelations showing distinct but small delta-like peaks along the whole image. Better than before DBBC cycled so just leaving and watching for now. (Liz) 
 +  * 20:44 UT and 21:19UT "​WARNING:​ error an -103 pointing computer tracking errors are too large. WARNING: error qo -301 warning: onsource status is slewing! ALARM: error m5 -900 not while recording or playing"​ Acknowledged alarm, seems not to have affected anything (Liz). 
 +  *  
 + 
 +2016.264.20:​43:​04 WARNING: error m5 -906 mark5 return code 6: inconsistent or conflicting request
  
 **Yarragadee 12m:** **Yarragadee 12m:**
  
-Disk VSN: GSFC+017+Disk VSN: HOB+0100
  
-  * Experiment started late as slow changing modules.+  * 17:​52UT ​Experiment started late as slow changing modules ​since yg operator didn't know we needed a new module after he took the r1 module out... First scan: 264-1752 (Liz)
  
  
Line 29: Line 35:
  
 ~~DISCUSSION~~ ~~DISCUSSION~~
- 
/home/www/auscope/opswiki/data/pages/handover/aov011.txt · Last modified: 2016/09/21 16:45 by Jesse Swan