handover:aov035 [2019/05/14 17:17] Warren Hankey |
handover:aov035 [2019/05/14 23:14] Jayender Kumar |
||
---|---|---|---|
Line 3: | Line 3: | ||
**Hobart 26m** | **Hobart 26m** | ||
- | Disk VSN: HOB+0125/32000/1024 | Data volume at beginning: | + | Disk VSN: HOB+0125/32000/1024 | Data volume at beginning: 15.9 TB |
+ | |||
+ | * 1725UT - Cryo monitoring system not working at Ho (ERROR ma -4 Device rx timed-out on response). I have replaced the cryomon and rxmon procedures with nops in EXPERIMENT procedure library for the time being, because otherwise it waits for each rx measurement to time out. I have also commented out the rxmon command in the midob procedure in STATION library, as that is also waiting for timeout, and screwing up scan timing. (Patrick) | ||
+ | * 1725UT - ''wx'' command not working. Returning ''wx#Problem connecting to metserver socket, wx#Illegal error class code: 0xffffffff'' (Patrick) | ||
+ | * 1730UT - Experiment started OK (Patrick) | ||
+ | * 1842UT - Windstowed from 18:42 - 19:25. | ||
+ | * Missed scans: 134-1841b thru 134-1924b (Patrick | ||
+ | * 1925UT - Field system time out of sync (''ERROR sc -13 setcl: formatter to FS time difference 0.5 seconds or greater''). Fixed by running ''sy=run setcl offset'' in oprin. | ||
+ | * Also at 20:46, 22:47, 22:52 | ||
+ | * 2300UT - Fixed rxmon/cryomon (ERROR ma -4 Device rx timed-out on response) by resetting TTY distributor with "reset" switch on old S/X MarkIV rack. Serial communications from Hobart to s/x receiver are still patched through this rack. (Warren and Brett) | ||
**Katherine 12m** | **Katherine 12m** | ||
- | Disk VSN:USN-0036/4000 | Data volume at beginning: 0.0 GB | + | Disk VSN:HOB+0015 | Data volume at beginning: 0.0 GB |
- | * 1700UT - Experiment started OK (Tiege) | + | * 1730UT - No system temperature measurements. Restarted DBBC pc, which fixed it. (Patrick) |
+ | * 1730UT - Experiment started OK (Patrick) | ||
**Yarragadee 12m** | **Yarragadee 12m** | ||
- | Disk VSN: USN-0017/4000 | Data volume at beginning: 0.0 GB | + | Disk VSN: HOB+0131 | Data volume at beginning: 0.0 GB |
- | * 1724UT - Experiment started late, pcfsyg disk filled up 15 minutes before experiment started and I did not notice until it was time for first scan. Needed to remove some old epi/png files from the auto_corr_test directory. First scan of experiment is 133-1724a. (Tiege) | + | * 1730UT - Experiment started OK (Patrick) |
+ | * 1730UT - no connection to Yg maser (Patrick) | ||