This shows you the differences between two versions of the page.
Next revision | Previous revision Last revision Both sides next revision | ||
handover:crds88 [2017/05/17 13:56] Arwin Kahlon |
handover:crds88 [2017/05/18 00:14] Arwin Kahlon |
||
---|---|---|---|
Line 3: | Line 3: | ||
**Hobart 26m** | **Hobart 26m** | ||
- | Disk VSN: | + | Disk VSN: HOB+0094 |
- | Volume at Beginning: | + | Volume at Beginning: 7025.286 GB |
+ | |||
+ | * 1800UT Experiment started OK (Bryn) | ||
+ | * 1800UT Got a Large Difference between formatter and maser delay (11.023 us), but fmset clock values all fine - VC rack is happy. (Bryn) | ||
**Hobart 12m** | **Hobart 12m** | ||
- | Disk VSN: | + | Disk VSN: HOB+1007 |
- | Volume at Beginning | + | Volume at Beginning: 11275.03 GB |
+ | |||
+ | * 1800UT Experiment started OK (Bryn) | ||
+ | * 0000UT getting the "s5 -112 rfpcn: EOF pre-draining input, rfpic probably crashed, connection closed" errors persistently, these are due to the hardware failure of the PIC unit in the telescope pedestal, unlikely to be resolved without hardware replacement, as noted in the previous experiment. (Arwin) | ||
**Katherine** | **Katherine** | ||
- | Disk VSN: | + | Disk VSN: HOB+0119 |
+ | |||
+ | Volume at Beginning: 1042.69 GB | ||
- | Volume at Beginning: | + | * 1800UT Experiment started OK (Bryn) |
{{tag>}} | {{tag>}} |