This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
handover:crds96 [2018/06/20 18:37] Noor Md Said |
handover:crds96 [2018/06/21 13:48] Patrick Yates |
||
---|---|---|---|
Line 9: | Line 9: | ||
When experiment started, received " WARNING: error qo -301 warning: onsource status is slewing!" for each scan. All clocks at FMSET are synchronise. | When experiment started, received " WARNING: error qo -301 warning: onsource status is slewing!" for each scan. All clocks at FMSET are synchronise. | ||
+ | 23:30UT - Autocorrelation spectra not updating. Lucas fixed based on similar error where procedure file didn't include checkmk5 command (Ross). | ||
+ | 13:45UT - 70K stage at ~90K and climbing, pressure at 3.6 microns mercury. Heading out to Mt Pleasant to fix. (Patrick) | ||
__Katherine 12m__ | __Katherine 12m__ | ||
Line 19: | Line 21: | ||
When experiment started, received "Warning: error tc -301 continuous cal not enabled for dbbc" for each scan | When experiment started, received "Warning: error tc -301 continuous cal not enabled for dbbc" for each scan | ||
+ | 23:21UT - After discussion with Warren decided to reboot dbbc to see if that fixed continuous cal error. Halted after scan no0385, first good scan no0388 (Ross). | ||
+ | |||
+ | 00:08UT - Noticed difference in procedure file between crds96 and previous crds experiments and corrected this error; missed scan no0394. Error still present, leaving for Warren to look at later (Ross). | ||
+ | |||
+ | 13:29UT - Fixed continous | ||