User Tools

Site Tools


handover:r1683

This wiki is not maintained! Do not use this when setting up AuScope experiments!

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
handover:r1683 [2015/04/13 20:01]
Ross Turner
handover:r1683 [2015/04/13 23:21]
Vasaant Krishnan
Line 29: Line 29:
   * 17:00 UT - Experiment started OK (Ross)   * 17:00 UT - Experiment started OK (Ross)
   * 17:20 UT - e-remote not working, killed all instances using pcfs and restarted (Ross)   * 17:20 UT - e-remote not working, killed all instances using pcfs and restarted (Ross)
 +  * 21:09 UT - Power outage at Yarragadee, entire system rebooted. Missed scans 103-2106a through 103-2211a corresponding to a deficit of 51.1 GB. Time difference between Mark5 and field system high but stable at 0.5 seconds (Ross)
 +  * 23:20 UT - Phonecall from Jim Lovell who's going to have a go at fixing the ACU time difference errors as well as the error from the System Monitor as a result of the power failure (vk)
  
 {{tag>}} {{tag>}}
/home/www/auscope/opswiki/data/pages/handover/r1683.txt · Last modified: 2015/04/14 06:21 by Vasaant Krishnan