+ | <note important>**Achtung! R1 TRANSFER IN PROGRESS! MONITORING REQUIRED!**</note> | ||
+ | R1 monitoring instructions: [[operations:monitoring.ivs.etransfer|operations:monitoring.ivs.etransfer]] | ||
+ | |||
+ | |||
+ | 12:34 UT: run fringe check on Hb-Ke baseline. No fringes found :-( (Lucia) | ||
**Hobart 12m:** | **Hobart 12m:** | ||
Line 6: | Line 13: | ||
Data volume at beginning: 0TB | Data volume at beginning: 0TB | ||
+ | |||
+ | * clkoff counter defect (gpib device inaccessible). time-out warning. Went to Mt Pleasant and at least could get the display back. **Clkoff not working, manual reading necessary**. (Lucia) | ||
+ | * 17:13 UT: LO unlocked, RF switches unknown. Restarted Monica, ok now. (Lucia | ||
+ | * 01:17 UT: LO reportedly unlocked, RF switches reportedly OK. Problem with the new version of RXMon, Jamie repaired it. Receiver was always locked. (Liza) | ||
+ | * 11.11 UT LO reportedly locked, restarting Rxmon and IFBox... All good! (Liza) | ||
+ | * Tsys in S-band is constantly high, in range 130-150K (Liza) | ||
+ | |||
**Katherine 12m:** | **Katherine 12m:** |