This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
handover:r1724 [2016/01/26 17:17] Tiege McCarthy |
handover:r1724 [2016/01/26 22:25] Tiege McCarthy |
||
---|---|---|---|
Line 6: | Line 6: | ||
Module: HOB+0075, 4745.416 GB | Module: HOB+0075, 4745.416 GB | ||
+ | * 17:00 UT - Before observation checklist delays were stated at the wrong time, should have been 16:45UT (Tiege) | ||
* 17:00 UT - Experiment started OK (Tiege) | * 17:00 UT - Experiment started OK (Tiege) | ||
Line 12: | Line 13: | ||
Module: GSFC+022, 3095.901 GB | Module: GSFC+022, 3095.901 GB | ||
+ | * 17:00 UT - Before observation checklist delays were stated at the wrong time, should have been 16:45UT (Tiege) | ||
* 17:00 UT - Experiment started OK (Tiege) | * 17:00 UT - Experiment started OK (Tiege) | ||
- | * 17:01 UT - Delay difference shifted from ~0.3 microseconds to ~0.619 however it seems stable at this delay difference. | + | * 17:01 UT - Delay difference shifted from ~0.3 microseconds to ~0.619 however it seems stable at this delay difference. (Tiege) |
+ | * 17:25 UT - Delay continued to drift, halted schedule, Reset the DBBC, restarted observations, missed scans 026-1715b & 026-1721, prior scans likely unreliable. (Tiege) | ||
+ | * 17:39 UT - Drifting happened again, not stabilising after 10+mins, halt schedule and rebooted DBBC, reconfigured and restarted schedule. Missed scans 026-1735b and 026-1738 (Tiege) | ||
+ | * 18:07 UT - Yet again drifting occuring badly, tried doing a hard reboot of the DBBC using the ipswitch, currently monitoring, appears to be still drifting. missed 026-1808b through to 026-1822a (Tiege) | ||
+ | * 18:43 UT - Called Warren (on-call) as delay was still consistently drifting, setup Kathernine again from scratch, reset field system, mk5, dbbc etc. restarted schedule at 19:00 UT, still appears to be drifting, Warren directed me to leave it until the morning. Scans missed 026-1843c through to 026-1854b (Tiege) | ||
+ | * 2210-2229 UT - No data recorded while adjusting maser settings. Modulation turned off & no further clock jumps/slips noted. (JMc) | ||
**Yarragadee** | **Yarragadee** | ||
Line 19: | Line 26: | ||
Module: USN-0049, 0.000 GB | Module: USN-0049, 0.000 GB | ||
+ | * 17:00 UT - Before observation checklist delays were stated at the wrong time, should have been 16:45UT (Tiege) | ||
* 17:00 UT - Experiment started OK (Tiege) | * 17:00 UT - Experiment started OK (Tiege) | ||
{{tag>}} | {{tag>}} |