User Tools

Site Tools


handover:r4717

This wiki is not maintained! Do not use this when setting up AuScope experiments!

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
handover:r4717 [2015/12/11 06:30]
David Horsley
handover:r4717 [2015/12/11 06:50]
David Horsley
Line 6: Line 6:
  
   * Exp started OK (Dave)   * Exp started OK (Dave)
-  * 06:10 UT - large clock jump noticed, schedule ​ halted and dbbc reset (Ross)+  * 06:10 UT - large clock jump noticed, schedule ​ halted and dbbc reset. Missed scans 345-0609b through 345-0622 ​(Ross)
  
  
Line 14: Line 14:
  
   * Exp started OK (Dave)   * Exp started OK (Dave)
 +  * 06:30 UT - large clock jump noticed, schedule ​ halted and dbbc reset. Missed scans 345-0630 and 345-0632b (Ross)
 +  * 06:45 UT - clock still unstable, resetting dbbc again (Ross)
  
  
Line 22: Line 24:
   * Exp started OK (Dave)   * Exp started OK (Dave)
  
 +General comment: Screens showing in incorrect order on AuScope computer and can not be corrected by restart (e.g. upper-right connects to middle, connects to bottom-left etc.).
  
 {{tag>}} {{tag>}}
Line 27: Line 30:
  
 ~~DISCUSSION~~ ~~DISCUSSION~~
- 
/home/www/auscope/opswiki/data/pages/handover/r4717.txt · Last modified: 2015/12/11 11:10 by David Horsley