This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
handover:rd1908 [2019/08/27 21:49] Patrick Yates |
handover:rd1908 [2019/08/28 02:09] Patrick Yates |
||
---|---|---|---|
Line 6: | Line 6: | ||
* 1730UT - Experiment started OK (Prad) | * 1730UT - Experiment started OK (Prad) | ||
- | * 2019UT - Antenna stowed due to high wind. Experiment resumed at 2148UT (Prad). | + | * 2019UT - Antenna stowed due to high wind. Experiment resumed at 2155UT (Prad). |
+ | * 2157UT - Noticed slewing in the 239-2157 scan (Prad). | ||
+ | * 2345UT - Cryogenic He supply pressure drops to 274.0 psi. Call Warren to check (Simin). | ||
+ | * 0045UT - He supply pressure drops to 271.5 psi (Simin). | ||
+ | * 0145UT - He supply pressure is above 275 psi now (Simin). | ||