User Tools

Site Tools


hardware:hardware.dbbc.power_measure

This wiki is not maintained! Do not use this when setting up AuScope experiments!

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Last revision Both sides next revision
hardware:hardware.dbbc.power_measure [2012/03/29 02:50]
Stuart Weston
hardware:hardware.dbbc.power_measure [2012/03/29 02:55]
Stuart Weston
Line 3: Line 3:
 === New Zealand DBBC 09/06/2011 === === New Zealand DBBC 09/06/2011 ===
  
-Testing of DBBC power measurement device reveals that it has a %red%logarithmic output response!!+Testing of DBBC power measurement device reveals that it has a **logarithmic output response**!!
  
 Update:​13/​6/​2011:​ Logarithmic response verified, 37 mV/dB according to data sheet {{:​hardware:​hmc610lp4-datasheet.pdf|}} Update:​13/​6/​2011:​ Logarithmic response verified, 37 mV/dB according to data sheet {{:​hardware:​hmc610lp4-datasheet.pdf|}}
Line 12: Line 12:
  
 {{:​hardware:​linearity-test-jun-2011.xls|}} {{:​hardware:​linearity-test-jun-2011.xls|}}
 +{{:​hardware:​linearity-test-jun-2011-1.xls|}}
 {{:​hardware:​dbbc-linearity.jpg|}} {{:​hardware:​dbbc-linearity.jpg|}}
  
/home/www/auscope/opswiki/data/pages/hardware/hardware.dbbc.power_measure.txt · Last modified: 2012/04/01 23:31 by Stuart Weston