This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Last revision Both sides next revision | ||
operations:agenda2020_09_24 [2020/09/24 03:11] Earl Lester |
operations:agenda2020_09_24 [2020/10/08 00:56] Jayender Kumar |
||
---|---|---|---|
Line 1: | Line 1: | ||
- | **Chair:** Earl | + | **Chair:** Jay |
+ | **Next meeting chair:** Eloise | ||
- | **Next meeting chair:** Jay | ||
- | + | **Attended:** | |
- | **Attended:** Lim, Simin, Prad, Katie, Patrick, Mas, Jamie, Jay | + | |
Line 13: | Line 12: | ||
**General Issues** | **General Issues** | ||
- | * AUM exps... Ke dbbc2 failed, no mixmode. Sent to Hobart for repairs ie no Ke mixmode for a while. | + | * CAL controller failure for HO 26 during AOV051 |
- | * Ho 12 checklist should be revised. Mixmode observering notes need clearing up. | + | * Autocorrelations have been funky for couple of H0 26 experiments ( AOV051 & R1966) |
* | * | ||
Line 20: | Line 19: | ||
- | * 12 and 26: | + | * Hb 12: |
- | * | + | |
- | * AOV051: Autocorrelations have been funky, suspect file has been messed with? Ignored for now (Eloise/Warren) | + | * AOV051: Experiment started with recording in only one stream. Check and make sure that it's record each scan in three stream(sxy,xx,xy) at the start of experiment. |
- | * | + | |
- | * X-band power amplifier died: no usable data due to receiver package. Power transistors replaced. Still on working on it. | + | |