This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
operations:currentissues [2015/11/03 03:02] Lucia McCallum |
operations:currentissues [2018/06/19 01:38] Tiege McCarthy |
||
---|---|---|---|
Line 1: | Line 1: | ||
====== Current Issues ====== | ====== Current Issues ====== | ||
+ | |||
+ | |||
+ | ===== Yarragadee Maser VNC Not Working ===== | ||
+ | |||
+ | ** Symptom ** | ||
+ | * VNC for maser pc is not working from the drop-down menu | ||
+ | * Manually attempting to VNC to the maser pc returns some form of unreachable message | ||
+ | |||
+ | ** Solution ** | ||
+ | * Contact staff at Yg and ask them if they can reboot the maser pc | ||
+ | * Once the pc comes back online, it should now be reachable by VNC | ||
+ | * Start maser server software, top right corner on Desktop | ||
+ | * Start maser management software (and check everything is still nice and green) | ||
+ | |||
+ | ===== Yarragadee IF rack ===== | ||
+ | |||
+ | The PIC in the IF rack at Yg has a problem that prevents diode switching and hence Tsys measurements. The | ||
+ | preob procedure in station.prc has been edited to comment out systemp12. Will need re-enabling when tsys is back (Jim) | ||
+ | |||
+ | ===== Yarragadee Network ===== | ||
+ | |||
+ | If the network connection to Yarragadee dies, the VPN could need reseting: | ||
+ | |||
+ | * [[operations:yg_VPN_reset|How to reset the Yarragadee VPN]] | ||
===== Humidity monitor at Yarragadee ===== | ===== Humidity monitor at Yarragadee ===== | ||
- | Humidity monitor at Yarragadee shows 0.0 - needs a fix? | + | The weather sensor at Yarragadee is currently away for repair (humidity sensor is broken). Weather is still being logged but from a separate sensor that is not connected to the Field System. Until our sensor is repaired and returned, there is an extra procedure to go through to recover the weather information: |
- | (added 14th Oct 2015) | + | * [[operations:documentation:yg_manual_weather|Manual extraction and logging of Yg weather data]] |
+ | (added 14th Oct 2015, updated 9 Aug 2016) | ||
===== wrong length written, file probably too large ===== | ===== wrong length written, file probably too large ===== | ||
Line 165: | Line 190: | ||
pfmed: exit | pfmed: exit | ||
</code> | </code> | ||
+ | |||
+ | Note that for Hobart26, the settings will be different (due to the LO frequencies of 8080/2020 MHz rather than 7600/1900 for the 12ms). e.g | ||
+ | |||
+ | <code> | ||
+ | pfmed | ||
+ | pfmed: pf,r1593ke | ||
+ | pfmed: ed,ifdsx | ||
+ | </code> | ||
+ | <code> | ||
+ | ifa=1,agc,2,40000 | ||
+ | ifb=4,agc,1,48000 | ||
+ | ifc=2,agc,2,32500 | ||
+ | ifd=2,agc,2,35000 | ||
+ | </code> | ||
+ | <code> | ||
+ | pfmed: exit | ||
+ | </code> | ||
+ | |||
===== DBBC computer hangs/crashes ===== | ===== DBBC computer hangs/crashes ===== | ||
Line 195: | Line 238: | ||
- To upload the latest image manually, you can run the FTP script manually by opening the ''ftp_script'' program in ''C:\thumbs'' | - To upload the latest image manually, you can run the FTP script manually by opening the ''ftp_script'' program in ''C:\thumbs'' | ||