operations:documentation:lba_starting_and_monitoring [2013/03/14 03:11]
Jim Lovell
operations:documentation:lba_starting_and_monitoring [2013/03/14 04:14]
Jim Lovell [Starting]
Line 5: Line 5:
  
 ===== Starting ===== ===== Starting =====
 +If you are stopping the previous schedule early (e.g. finishing a Fringe Check schedule ahead of time), use ''​halt''​ to stop the schedule and then make sure the disk has stopped recording:
 +<​code>​
 +halt
 +disk_record=off
 +</​code>​
 +
 +Now make sure you have the correct Mark5 module selected. Type <​code>​mk5=vsn?</​code>​ and check the serial number against what you think it should be. For the March LBA session, a list of modules agains experiments is given in the [[http://​ra-wiki.phys.utas.edu.au/​index.php?​n=Schedules.LBAMar13|Observing Roster]] page. If you need to change modules use the ''​mk5=bank_set''​ command. e.g. to change to Bank B:<​code>​mk5=bank_set=b</​code>,​ then run <​code>​mk5=dot?</​code>​to check.
 +
 If time permits, make a recording test before starting and check the bit stats and autocorrelations (note this won't work from a fringe-checking schedule): If time permits, make a recording test before starting and check the bit stats and autocorrelations (note this won't work from a fringe-checking schedule):
  
Line 21: Line 29:
  
 <​code>​ <​code>​
-schedule=v252aike+schedule=v252aike,#1
 </​code>​ </​code>​
  
Line 57: Line 65:
 If monitoring from Mt. Pleasant, use pmSTALMke.sh to monitor the alarms. If you want the station alarms to go off when there’s an error (rather than playing a sound through the speakers), use pmSTALMke.newsmerd.sh. I’d recommend changing the title of the terminal window to make it clear which alarms are from which station If monitoring from Mt. Pleasant, use pmSTALMke.sh to monitor the alarms. If you want the station alarms to go off when there’s an error (rather than playing a sound through the speakers), use pmSTALMke.newsmerd.sh. I’d recommend changing the title of the terminal window to make it clear which alarms are from which station
  
-See the [[operations:​currentissues|Current Issues]] section for known problems and how to fix them.  
- 
-See also these notes on 
/home/www/auscope/opswiki/data/pages/operations/documentation/lba_starting_and_monitoring.txt · Last modified: 2014/11/22 09:01 by Jesse Swan