operations:documentation.clock_and_delay_check [2014/12/17 09:55] Warren Hankey [Maser to GPS, Formatter to GPS delays and difference] |
operations:documentation.clock_and_delay_check [2016/03/30 03:39] Lucia McCallum [Maser to GPS, Formatter to GPS delays and difference] |
||
---|---|---|---|
Line 19: | Line 19: | ||
- | **Be sure that mk5=dot? returns FHG_off before you run fmset. Sometimes if a power glitch occurs while the Mark5 is recording, it can get stuck. If FHG_on, end with disk_record=off and then run fmset again | + | Be sure that mk5=dot? returns FHG_off before you run fmset. Sometimes if a power glitch occurs while the Mark5 is recording, it can get stuck. If FHG_on, end with disk_record=off and then run fmset again |
+ | |||
+ | During the observation, it is useful to monitor the delay difference on a plot. to do it, you can start a terminal on ops2 (or ops1hb at MtPleasant) and | ||
+ | |||
+ | **(OLD)** <code>cd /vlbobs/ivs/logs</code> Then start gnuplot: <code>gnuplot</code> You shall start and/or refresh the plot window for each station by hand each time you wish to see the plot: | ||
+ | |||
+ | <code> | ||
+ | set term 'wxt' 0 ; plot "hb_ddif.txt" | ||
+ | set term 'wxt' 1 ; plot "ke_ddif.txt" | ||
+ | set term 'wxt' 2 ; plot "yg_ddif.txt" | ||
+ | </code> | ||
+ | |||
+ | **NEW:** there is now a live update available (no need to export and re-plot the data). Fro this, open a terminal on ops2 and type | ||
+ | <code> | ||
+ | delaylive hb (ke, yg) | ||
+ | </code> | ||
=====GPIB communication with Agilent counters ===== | =====GPIB communication with Agilent counters ===== | ||
If the GPIB has been restarted (via the PDU internet power switch, or a power outage) a field system restart is probably required to re-establish communications with the counters connected to the GPIB. Symptomatic is ''fmset'' working OK, sync_error=0, but ''counter'', ''clkoff'','' maserdelay'' commands not working; the ddiff counter showing random large offsets and/or changing rapidly. Restarting the field system should bring the ddiff counter back to a steady several microseconds and enable GPIB comms. | If the GPIB has been restarted (via the PDU internet power switch, or a power outage) a field system restart is probably required to re-establish communications with the counters connected to the GPIB. Symptomatic is ''fmset'' working OK, sync_error=0, but ''counter'', ''clkoff'','' maserdelay'' commands not working; the ddiff counter showing random large offsets and/or changing rapidly. Restarting the field system should bring the ddiff counter back to a steady several microseconds and enable GPIB comms. | ||