This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Last revision Both sides next revision | ||
operations:documentation.dbbcsetupivs [2013/12/04 06:01] Warren Hankey |
operations:documentation.dbbcsetupivs [2014/10/21 17:32] liza |
||
---|---|---|---|
Line 52: | Line 52: | ||
</code> | </code> | ||
- | The target values for the total power readings is 56000. this can be checked by the command dbbcif[abcd]. If the levels are too high or low, then adjust the attenuation on the IF box. Note that the levels on IF C (dbbcifc) are a bit low. Don't worry about it. | + | Recommended DBBC power levels can be found [[hardware:dbbc.targetifpower|here]]. Current target values for the total power readings is 56000. this can be checked by the command: ifa, ifb, ifc or ifd. If the levels are too high or low, then adjust the attenuation on the IF box. Note that the levels on IF C (e-remote control command: ifc) are a bit low. Don't worry about it. |