User Tools

Site Tools


operations:documentation.dbbcsetupivs_9.10.5

This wiki is not maintained! Do not use this when setting up AuScope experiments!

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision Both sides next revision
operations:documentation.dbbcsetupivs_9.10.5 [2013/10/03 00:28]
Jim Lovell
operations:documentation.dbbcsetupivs_9.10.5 [2013/10/03 04:21]
Jim Lovell
Line 4: Line 4:
 If you can't connect to the DBBC VNC server, the DBBC may have died. In which case, follow these notes on [[operations:​documentation:​dbbc_restart|Recovering from a DBBC Failure]] If you can't connect to the DBBC VNC server, the DBBC may have died. In which case, follow these notes on [[operations:​documentation:​dbbc_restart|Recovering from a DBBC Failure]]
  
-In ''​C:​\DBBC_CONF\''​ are several configuration files for different experiment types. The default configuration is kept in ''​dbbc_config_file_104.txt''​ and this will be loaded when the server software is started. ​+In ''​C:​\DBBC_CONF\''​ are several configuration files for different experiment types. The default configuration is kept in ''​dbbc_config_file_104.txt'' ​(for Hb and Yg) and ''​dbbc_config_file_102.txt''​ (for Ke) and this will be loaded when the server software is started. ​
  
-Check to see if a program called ''​DBBC2 ControlDDC v104_2.exe''​ is running. If it's not running, start it. There'​s a link to it from the desktop. (Don't have two instances running.) +Check to see if a program called ''​DBBC2 ControlDDC v104_2.exe''​ is running ​for Hb and Ke, or ''​DBBC2 ControlDDC v102.exe''​ for Ke. If it's not running, start it. There'​s a link to it from the desktop. (Don't have two instances running.) 
-<note important>​Make sure you are running v104_2 of the DBBC Control software at Hb and Ke and Yg.</​note>​+<note important>​Make sure you are running v104_2 of the DBBC Control software at Hb and Yg, and v102 at Ke.</​note>​
 If the DBBC has had a power cycle or if there have been timing problems, or if you just want to be cautious, say "​y"​ when asked if you want to reconfig with the defaults. Configurations will take about 2 minutes. ​ If the DBBC has had a power cycle or if there have been timing problems, or if you just want to be cautious, say "​y"​ when asked if you want to reconfig with the defaults. Configurations will take about 2 minutes. ​
  
Line 35: Line 35:
   * ''​dbbc_config_file_104_T2_OHIG.txt''​ for T2 and OHIG   * ''​dbbc_config_file_104_T2_OHIG.txt''​ for T2 and OHIG
   * ''​dbbc_config_file_104_point.txt''​ for pointing observations   * ''​dbbc_config_file_104_point.txt''​ for pointing observations
- 
/home/www/auscope/opswiki/data/pages/operations/documentation.dbbcsetupivs_9.10.5.txt · Last modified: 2016/07/27 18:19 by Warren Hankey