This shows you the differences between two versions of the page.
Next revision | Previous revision Last revision Both sides next revision | ||
operations:documentation.ivs.bonnetransfer [2011/06/03 04:36] Jim Lovell created |
operations:documentation.ivs.bonnetransfer [2012/11/13 23:35] Jamie McCallum |
||
---|---|---|---|
Line 1: | Line 1: | ||
====== Transferring Data to Bonn ====== | ====== Transferring Data to Bonn ====== | ||
+ | * Use a VNC session to run the transfers - the hobart.phys.utas.edu.au:1 session is normally a good option. | ||
* Open four terminal windows on the Mark5 unit the data will be sent from | * Open four terminal windows on the Mark5 unit the data will be sent from | ||
- | * In the first terminal, make sure dimino isn't running <code>ps -ef | grep dim</code> and that another transfer isn't running <code>ps -ef | grep tsuna</code>. Then use fuse to mount the module: <code>fuseMk5A --bank=0 --verbose /mnt/diskpack</code> This will mount Bank A (set bank=1 for Bank B) at /mnt/diskpack | + | * In the first terminal, make sure that neither fuseMk5 or dimino is running <code>ps -ef | grep dim</code> and <code>ps -ef | grep fuse</code> and that another transfer isn't running <code>ps -ef | grep tsuna</code>. |
+ | * If fuseMk5A is running and the wrong module is mounted, dismount with <code>fusermount -u <directory_name></code> | ||
+ | * Then use fuseMk5 (or fuseMk5A for unupgraded mark5 units) to mount the module: <code>fuseMk5 --bank=0 --verbose --cachesize=128000000 /mnt/diskpack</code> This will mount Bank A (set bank=1 for Bank B) at /mnt/diskpack. Wait for a message to say <code>.... Registering fuseMk5A to FUSE with: ....</code>. It can take a while. Background this process with Ctrl-z and <code> bg </code>. | ||
* In a second terminal, change to the mounted directory and make sure the data are there <code>cd /mnt/diskpack | * In a second terminal, change to the mounted directory and make sure the data are there <code>cd /mnt/diskpack | ||
ls | ls | ||
Line 9: | Line 11: | ||
* In the third terminal window, log on to the computer at Bonn that will receive the data and change to the directory where the data will be sent <code>ssh evlbi@<machine.address> | * In the third terminal window, log on to the computer at Bonn that will receive the data and change to the directory where the data will be sent <code>ssh evlbi@<machine.address> | ||
cd /data3/r1/hobart12/r1485/ | cd /data3/r1/hobart12/r1485/ | ||
- | </code> | + | </code> The [[http://www3.mpifr-bonn.mpg.de/cgi-bin/showtransfers.cgi |
+ | |Bonn web page]] shows available servers and space. | ||
+ | (194.94.199.166 = sneezy2) | ||
* Start tsunami and set up for a transfer | * Start tsunami and set up for a transfer | ||
<code> | <code> | ||
tsunami | tsunami | ||
- | set port 52100 | + | set rate 300m |
- | set server 131.217.63.175 (or whatever the IP of the Mark5 is) | + | connect 131.217.63.175 52100 |
+ | get * | ||
</code> | </code> | ||
- | * in the fourth terminal window, create an empty file with a name describing the start time of the transfer, rate etc: <code>touch 20110525033000_r1485_Hb_Bonn_300m_52100_start</code> | + | * in the fourth terminal window, create an empty file with a name describing the start time of the transfer, rate etc: <code>touch 20110525033000_r1485_Hb_Bonn_300m_52100_sneezy2_start</code> This puts an entry on the [[http://www3.mpifr-bonn.mpg.de/cgi-bin/showtransfers.cgi |
- | * and send it to the web server <code>ncftpput ftp.mpifr-bonn.mpg.de /incoming/geodesy/transfers 0110525033000_r1485_Hb_Bonn_300m_52100_start</code> | + | |Bonn web page]] to say there's a transfer under way |
- | * | + | * and send it to the web server <code>ncftpput ftp.mpifr-bonn.mpg.de /incoming/geodesy/transfers 0110525033000_r1485hb_Hb177_Bonn_300m_52100_sneezy2_start</code> |
+ | * When the transfer finishes, send a stop message with <code>touch 20110525033000_Hb_stop | ||
+ | ncftpput ftp.mpifr-bonn.mpg.de /incoming/geodesy/transfers 20110525033000_Hb177_stop</code> | ||
+ | |||
+ | It is also possible (and preferable) to export the data onto a RAID first. Currently, there are three RAIDS which can beused for temporary storage at Hobart - Vortex, Cornucopia and 131.217.63.140 (Currently unnamed and contains two separate RAIDS of 6 and 12 TB). These can be NFS mounted on the mk5 machine with <code>mount vortex.phys.utas.edu.au:/exports/vortex_internal/ /mnt/vortex</code> (as root). Once mounted the data can be copied with <code>cp /mnt/diskpack/r1485* /mnt/vortex/r1485hb/</code>. | ||
+ | |||
+ | Once fully copied, please check the data has not been corrupted in the transfer. ssh into hex0 and NFS mount the RAID if necessary. Then run <code>directory2filelist /mnt/vortex/r1485hb Mark5B-256-16-1 > /tmp/ok.txt</code> . The output to the screen will be the list of those scans which show problems. It's not uncommon to see up to ~10% of the scans fail the test - these files should be deleted and retransferred to the RAID. | ||
+ | |||
+ | The same <code>directory2filelist</code> procedure should be run after a transfer to Bonn completes to check for errors in transmission. |