This shows you the differences between two versions of the page.
operations:log_recent_events [2011/02/23 01:12] Jim Lovell |
operations:log_recent_events [2011/10/26 06:37] |
||
---|---|---|---|
Line 1: | Line 1: | ||
- | ^Date ^Time ^Experiment / Event ^S-band VLBI SEFD ^X-band VLBI SEFD ^Comment ^ | ||
- | |Jan 17 | 23.00 | Pointing | | |//Pointing updated// with +0.155 deg El offset | | ||
- | |Jan 18 | 17.00 | R1466 | 4844 | 5287 | | | ||
- | |Jan 20 | 18.30 | R4466 | 10679 | 18892 | No data after 01.55 UT until end due to problems with Az drive tripping out | | ||
- | |Jan 24 | 17.00 | R4467 | 5734 | 5231 | Missed scans due to Az drives 20.12 - 22.13 and 14.00 - 14.18 UT| | ||
- | |Jan 27 | 03.00 | Pointing | | | Check shows a 0.02 deg offset. Probably not significant and no model update made | | ||
- | |Jan 31 | 17.00 | R1468 | 6173 | 4886 | Drive problems. Scans from 16.09-16.27 missed | | ||
- | |Feb 01 | 17.30 | T2074 | | | DBBC freqs incorrect for VC13, VC14. Rapid drift in formatter-GPS offset. Some scans missed due to drive problems.| | ||
- | |Feb 02 | 18.00 | OHIG70 | | | DBBC freqs incorrect for VC13, VC14. All scans after 15.19 lost, drive problems| | ||
- | |Feb 03 | 18.30 | R4468 | 6540 | 6126 | Many missed scans due to drive problems | | ||
- | |Feb 07 | 23.40 | Pointing | | | Offsets observed: xEL = -0.003, El = 0.02. No update to model | | ||
- | |Feb 08 | 17.30 | OHIG71 | | | Frequencies OK. Multiple drive failures | | ||
- | |Feb 17 | 03.10 | Pointing | | | //Pointing updated// with +0.05 deg El offset following tightening of encoder mounting brackets | | ||
- | |Feb 17 | | PCFS | | | Problem with Az drives tripping was fixed (software bug) | | ||
- | |Feb 17 | 18.30 | R4470 | | | | | ||
- | |Feb 21 | 04.13 | Pointing | | | Offsets observed: xEL = -0.01, El = -0.015. No update to model | | ||
- | |Feb 21 | 17.00 | R1471 | | | | | ||
- | |Feb 24 | 18.30 | R4471 | | | | | ||