User Tools

Site Tools


operations:pointing

This wiki is not maintained! Do not use this when setting up AuScope experiments!

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision Both sides next revision
operations:pointing [2016/06/23 00:04]
Jim Lovell [Version 2016.151]
operations:pointing [2016/07/24 23:34]
Jim Lovell [Version 2016.151]
Line 60: Line 60:
  
 ===== Hobart 12m model ===== ===== Hobart 12m model =====
 +
 +==== Temporary HMI model ====
 +This is a temporary model applied in HMI during broadband tests with the Callisto system. ​
 +
 +Original model:
 +<​code>​
 +P1 -0.0335
 +P2 -0.4380
 +P3 0.0066
 +P4 -0.0026
 +P5 -0.0023
 +P6 0
 +P7 0.1538
 +P8 0.0214
 +P9 0.0026
 +</​code>​
 +
 +Additional offsets are 
 +<​code>​
 +Az = +2.7 arcmin = 0.045 deg
 +El = -4.0 arcmin = -0.0667 deg
 +</​code>​
 +
 +The DC terms in the pointing model are P2 (Az) and P7 (El), so new model is:
 +<​code>​
 +P1 -0.0335
 +P2 -0.393
 +P3 0.0066
 +P4 -0.0026
 +P5 -0.0023
 +P6 0
 +P7 0.08713
 +P8 0.0214
 +P9 0.0026
 +</​code>​
 +
 +
  
 ==== Version 2016.151 ==== ==== Version 2016.151 ====
Line 81: Line 118:
  
 {{:​operations:​opsmac1.png?​200|}} {{:​operations:​opsmac1.png?​200|}}
- 
  
  
/home/www/auscope/opswiki/data/pages/operations/pointing.txt · Last modified: 2017/05/30 07:12 by Jamie McCallum