This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
operations:revised_procedure_using_scripts [2017/11/24 05:44] Arwin Kahlon |
operations:revised_procedure_using_scripts [2017/11/24 05:56] Arwin Kahlon |
||
---|---|---|---|
Line 24: | Line 24: | ||
=== Setting up the observing windows === | === Setting up the observing windows === | ||
- | * Check that the appropriate software is running on the pcfs, timing, and the DBBC computers. <code>**Timing PC:** HMI ("UOT 12m Antenna-xxx"), Tac32Plus, and the AneMonitor. | + | * Check that the appropriate software is running on the pcfs, timing, maser, and the DBBC computers. <code>**Timing PC:** HMI ("UOT 12m Antenna-xxx"), Tac32Plus, and the AneMonitor. |
- | **PCFS:** field system | + | **PCFS:** field system |
- | **DBBC:**DBBC2 Control DDC v104_2.exe </code> | + | **DBBC:**DBBC2 Control DDC v104_2.exe |
+ | **Maser** H-server, Standard VCH-1005A Manager </code> | ||
* Close the existing windows on the screen by opening up a terminal and typing <code>windex</code> and then manually closing any stragglers. | * Close the existing windows on the screen by opening up a terminal and typing <code>windex</code> and then manually closing any stragglers. | ||
* To open e-RemoteCtrl, Log Monitor, System Monitor, delaylive, and tsys monit3) enter <code>windows hb ke yg</code> omitting any telescopes not in use. | * To open e-RemoteCtrl, Log Monitor, System Monitor, delaylive, and tsys monit3) enter <code>windows hb ke yg</code> omitting any telescopes not in use. | ||
Line 40: | Line 41: | ||
* [[operations:rf_if_check_9.10.5|Configuring the RF and IF signal paths]] | * [[operations:rf_if_check_9.10.5|Configuring the RF and IF signal paths]] | ||
* [[operations:documentation.DBBCSetupIVS_9.10.5|DBBC Setup]] | * [[operations:documentation.DBBCSetupIVS_9.10.5|DBBC Setup]] | ||
+ | * In moprin please type <code>setupsx | ||
+ | iread | ||
+ | bread</code> | ||
+ | * To configure the mk5, open a terminal and type <code>mk5setup.py r1418 hb-ke-yg</code> with the correct experiment code and the required stations of course. Please not the output of the ''EndDIM'' might say ''dim not found'' or something similar. This is okay as it just means that the process wasn't running when the EndDim command was issued. If the script doesnt break out of a loop, the mk5 hasnt been setup properly. | ||
+ | * You can switch modules using <code>mk5=bank_set=inc</code>. Please make sure you are using the correct module [[http://auscope.phys.utas.edu.au/opswiki/doku.php?id=operations:log|Module Allocation Spreadsheet]] | ||