operations:temphumidmonitor [2018/09/11 07:13]
Jim Lovell [Hardware setup]
operations:temphumidmonitor [2018/09/11 07:24]
Jim Lovell
Line 36: Line 36:
 </​code>​ </​code>​
 Connect them to the Raspberry Pi. Any GND or +5V pin will be fine. Connect them to the Raspberry Pi. Any GND or +5V pin will be fine.
-Use any digital pin on the Pi and make sure they are set to "​False"​ in ''​TempHumid.conf''​ (you can give them an appropriate label though).+Use any digital pin on the Pi and make sure they are set to "​False"​ in ''​TempHumid.conf''​ (you can give them an appropriate label though). See below.
  
 ==== Accelerometer ==== ==== Accelerometer ====
Line 50: Line 50:
 </​code>​ </​code>​
  
 +Attach the accelerometer to the maser (or whatever you want to measure). You might want to align it according to the orientation diagram on the module.
 ==== Analog (Eric) Temperature/​Humidity Sensor ==== ==== Analog (Eric) Temperature/​Humidity Sensor ====
 This should also be connected to the Arduino: This should also be connected to the Arduino:
Line 62: Line 63:
  
  
-===== Software =====+===== DHT11 monitoring ​Software =====
 Software, config file etc are stored in ''​~pi/​TempHumid''​ Software, config file etc are stored in ''​~pi/​TempHumid''​
  
Line 87: Line 88:
   * ''​start_THRecord.sh''​ and ''​start_THServer.sh''​ are started automatically after the RPi boots into a desktop session, so a reboot of the RPi should start these processes. They are called from ''​~/​.config/​lxsession/​LXDE-pi/​autostart''​. Edit this file if you want to change what happens when the desktop starts.   * ''​start_THRecord.sh''​ and ''​start_THServer.sh''​ are started automatically after the RPi boots into a desktop session, so a reboot of the RPi should start these processes. They are called from ''​~/​.config/​lxsession/​LXDE-pi/​autostart''​. Edit this file if you want to change what happens when the desktop starts.
  
-==== Network config ====+===== Accelerometer,​ Analog temp/humid monitoring Software ====== 
 +A work in progress... 
 + 
 +===== Software for IR remote control of aircon ====== 
 +A work in progress... 
 + 
 +====== Network config ====
 +This should be done already, but just in case... 
 For masertempke the IP address should be 131.217.61.28. For masertempke the IP address should be 131.217.61.28.
 For antennatempke the IP address should be 131.217.61.29. For antennatempke the IP address should be 131.217.61.29.
Line 108: Line 117:
  
 [[operations:​temphumidmonitorrpi|Configuring Raspberry Pis for Temperature and Humidity monitoring]] [[operations:​temphumidmonitorrpi|Configuring Raspberry Pis for Temperature and Humidity monitoring]]
- 
  