This shows you the differences between two versions of the page.
| Both sides previous revision Previous revision Next revision | Previous revision | ||
|
blog:dbbc_calibration_at_yg_jan_2013 [2013/01/31 00:20] Jim Lovell |
blog:dbbc_calibration_at_yg_jan_2013 [2013/01/31 00:48] (current) Jim Lovell |
||
|---|---|---|---|
| Line 68: | Line 68: | ||
| 31 Jan 2013: | 31 Jan 2013: | ||
| + | |||
| + | Randall replaced CoMo B IF cable and checked connections again. Nothing moved. Re-did phase calibration and new phases are: | ||
| + | |||
| + | 103 86 80 105 | ||
| + | |||
| + | Edited all cal files with these new values. | ||
| + | |||
| + | Re-ran phase cal amplitude peaking. Looks like S-band lower could be optimised a little by going to a target of 35000. All others seem OK | ||
| + | |||
| + | |||