This shows you the differences between two versions of the page.
| Both sides previous revision Previous revision Next revision | Previous revision | ||
|
handover:aum018 [2020/08/19 12:43] Patrick Yates |
handover:aum018 [2020/08/20 04:32] (current) Lim Chin Chuan |
||
|---|---|---|---|
| Line 6: | Line 6: | ||
| * 1730UT - Experiment started ok (Patrick). | * 1730UT - Experiment started ok (Patrick). | ||
| + | * 2350UT - Halted, wrong prc setup. (Lim) | ||
| + | * 0024UT - First scan with correct datastream: 233-0024 (Lim) | ||
| + | * 0300UT - fs crashes: Affected scans: 233-0301 to 233-0400 (Simin) | ||
| Line 13: | Line 16: | ||
| * 1730UT - Experiment started ok (Patrick). | * 1730UT - Experiment started ok (Patrick). | ||
| + | * 2157UT - Clock jump (Patrick). | ||
| Line 19: | Line 23: | ||
| flexbuff | flexbuff | ||
| + | * Running ''aum.setup.py'' configured ''dbbc3ke'' okay, but failed with ''fila10g/ERROR'' when trying to configure ''dbbcke''. Fixed by restarting the control software (''v106E_120118'') on ''dbbcke''. | ||
| * 1730UT - Experiment started ok (Patrick). | * 1730UT - Experiment started ok (Patrick). | ||
| + | * 2140UT - Antenna stuck, fixed with ''antenna=open'' and ''antenna=operate''. Affected scans: 232-1833 to 232-2142 (Patrick). | ||
| + | * 0015UT - It seems that only xx pol recorded so far, restarted jive5ab and recording xx and xy datastream now. (Lim) | ||
| + | * 0048UT - scans with 3 datastreams 233-0033 to 233-0048 (Lim). | ||
| + | * 0059UT - Fila10G failed again? s band not recorded again. (Lim) | ||
| + | * 0123UT - Unsolvable dbbc2 problem. For most scans, only the x band data recorded (Lim) | ||