This shows you the differences between two versions of the page.
| Both sides previous revision Previous revision Next revision | Previous revision | ||
|
handover:hob005 [2016/09/25 17:50] Lucas Hyland |
handover:hob005 [2016/09/25 22:40] (current) Lucas Hyland |
||
|---|---|---|---|
| Line 1: | Line 1: | ||
| ====== HOB005 ====== | ====== HOB005 ====== | ||
| - | |||
| - | Setup was very ambiguous. Is there a wiki-page dedicated to this special setup? | ||
| **Hobart 12m** | **Hobart 12m** | ||
| - | AUST/normal setup procedures followed but SNP file wasn't/isn't downloaded with drudge. No .sum file either. Only noticed when attempted to start schedule got "ERROR bo -105 Error opening schedule file FMP ? FFF". Called on-call person and emailed various. Issue remains unresolved. | + | AUST/normal setup procedures followed but SNP file wasn't/isn't downloaded with drudge. No .sum file either. Only noticed when attempted to start schedule got "ERROR bo -105 Error opening schedule file FMP ? FFF". |
| + | Turns out proc file had extra ifd=(blank) which, when deleted, allowed a successful drudge. | ||
| + | |||
| + | Jamie fixed all the problems. | ||
| + | |||
| + | Disk_module HOB+0.0088. | ||
| + | |||
| + | First good scan, 269-1909 at 19:09UT disk_pos=1542.798 GBs | ||
| **Hobart 26m** | **Hobart 26m** | ||
| - | As per notes on here: (http://auscope.phys.utas.edu.au/opswiki/doku.php?id=observing:hohb) the mk5 was swapped over. And schedule started. Initially got nominal response from mk5=dot? So started schedule. Got error "ERROR tc -302 TPICD not set-up: no detectors selected". After observer and on-call person attempted to fix, status went from bad to worse and errors concerning wrong mode selected in equip.ctl file started. And disk_record=off no longer worked as "Error m5 -900: Can't record with Mark-5B DOM". Also unresolved. | + | As per notes on here: (http://auscope.phys.utas.edu.au/opswiki/doku.php?id=observing:hohb) the mk5 was swapped over. And schedule started. Initially got nominal response from mk5=dot? So started schedule. Got error "ERROR tc -302 TPICD not set-up: no detectors selected". After observer and on-call person attempted to fix, status went from bad to worse and errors concerning wrong mode selected in equip.ctl file started. And disk_record=off no longer worked as "Error m5 -900: Can't record with Mark-5B DOM". |
| + | |||
| + | Started restarting entire setup and Jamie took over and fixed most problems apart from TIPCD error which he said he will work on an update for equip.ctl file. | ||
| + | |||
| + | Disk_module HOB+1010 | ||
| + | First 'good' scan 269-1930 at 19:30 UT disk_pos=2602.831 GBs | ||