This shows you the differences between two versions of the page.
| Both sides previous revision Previous revision Next revision | Previous revision | ||
|
handover:ohg114 [2018/11/06 21:14] Pradyumna Kiran Kummamuru |
handover:ohg114 [2018/11/07 05:38] (current) Pradyumna Kiran Kummamuru |
||
|---|---|---|---|
| Line 15: | Line 15: | ||
| * 2031UT - error qo -301 warning: Onsource status is slewing (Prad). | * 2031UT - error qo -301 warning: Onsource status is slewing (Prad). | ||
| * 2111UT - Formatter to fs time difference 0.5 seconds or greater. Scan 310-2111 might be affected (Prad). | * 2111UT - Formatter to fs time difference 0.5 seconds or greater. Scan 310-2111 might be affected (Prad). | ||
| + | * 0207 - Source not reached due to windstow (JMc) | ||
| + | * 0336 - Back on source (JMc) Scans between 0207 and 0336 will not be useful. | ||
| + | * ~0330 Receiver cryogenic pressure high, vacuum pump started (JMc) | ||
| + | * No Tsys readings, reason unclear (JMc) | ||
| + | * Schedule halted at 05:35 due to high winds (JMc) | ||
| Line 28: | Line 33: | ||
| * 1730UT - Experiment started OK (Prad). | * 1730UT - Experiment started OK (Prad). | ||
| + | * 03:55 - Network laggy, probably running on 3G backup. maser PC inaccessible (JMc) | ||