User Tools

Site Tools


handover:ohg121

This wiki is not maintained! Do not use this when setting up AuScope experiments!

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
handover:ohg121 [2019/10/07 22:47]
Tiege McCarthy
handover:ohg121 [2019/10/08 01:41] (current)
Jamie McCallum
Line 8: Line 8:
   - couldn'​t get information about pressure and 70K stage cryogenics (mas)   - couldn'​t get information about pressure and 70K stage cryogenics (mas)
   - in the Otter interface, working receiver appear as L band, but rxp command showed S/X band. Have informed Warren and Jamie (mas)   - in the Otter interface, working receiver appear as L band, but rxp command showed S/X band. Have informed Warren and Jamie (mas)
 +  - 22:00 UT s/x receiver is on axis (warren)
 +  - 23:00 UT receiver comms not working, unknown cryo temps, auto corr OK, but crazy system temp, no response from counters, dot sync_err=0 (w)
 +  - 23:47 UT drives switched themselves off mid scan  280-2346 ​ (w)
 +  - 00:10 (281) UT wind stow at end of 281-0003 (w)
 +  - 00:12 UT missed scans 281-0012 to  (w)
 +  - 00:30 UT - Experiment terminated due to ongoing issues with drives and receiver (JMc)
  
  
/home/www/auscope/opswiki/data/attic/handover/ohg121.1570488447.txt.gz · Last modified: 2019/10/07 22:47 by Tiege McCarthy