This shows you the differences between two versions of the page.
| Both sides previous revision Previous revision | |||
|
handover:r1806 [2017/08/21 17:25] Jesse Swan |
handover:r1806 [2017/08/24 23:20] (current) Patrick Yates |
||
|---|---|---|---|
| Line 10: | Line 10: | ||
| * 17:00 UT Experiment started OK. Dodgy module in mk5 rack was causing issues (HAY-0062), Jamie switched to use other module. (Patrick) | * 17:00 UT Experiment started OK. Dodgy module in mk5 rack was causing issues (HAY-0062), Jamie switched to use other module. (Patrick) | ||
| - | * 17:15 Hb mk5 errors: ''error m5 -900 : can't record while other data transfers, error m5 -900 : not while other activity, error m5 -900 : previous recording still active''. Affected scans: 233-1715 - 233-1722 (just for mk5 hb) (Patrick) | + | * Errors were: ''ERROR m5 -900 : Can't set SS mode, ERROR m5 -904 MARK5 return code 4: error encountered (during attempt to execute), ERROR m5 -104 mk5cn: time-out, connection closed'' |
| + | * 17:15 Error with the autocorrelation script and how it was being called for Hb mk5. Affected scans: 233-1715 - 233-1722 (just for mk5 hb). (Patrick) | ||
| + | * Hb mk5 errors: ''error m5 -900 : can't record while other data transfers, error m5 -900 : not while other activity, error m5 -900 : previous recording still active''. | ||
| **Katherine** | **Katherine** | ||