Line 5: Line 5:
 Disk VSN: HAY-0062 | Data volume at beginning: 1.571 GB Disk VSN: HAY-0062 | Data volume at beginning: 1.571 GB
  
-Proc file does not seem to have been generated properly, this is causing issues noticeable in the test recording. I am using the r1895ke proc file now instead. Please note this if you need to re-setup the experiment at some point.+Proc file does not seem to have been generated properly, this is causing issues noticeable in the test recording. I am using the r1895ke proc file now instead. Please note this if you need to re-setup the experiment at some point. ​(Tiege) 
 + 
 +->Proc issue due to a typo in skedf.ctl (DNNC rather than DBBC). skedf.ctl may not be applied until after a restart of the FS. (JMc)
  
    ​* ​ 1700UT - Experiment started OK (Tiege)    ​* ​ 1700UT - Experiment started OK (Tiege)
Line 13: Line 15:
 Disk VSN: HOB+0064 | Data volume at beginning: 1.699 GB Disk VSN: HOB+0064 | Data volume at beginning: 1.699 GB
  
-This setup happened after Jamie and Guifre were attempting top upgrade DBBC software. I closed the new DBBC software, opened the old, then restarted fs. Everything was fine (including test recording), however, while doing pointing check (after typing fivept) I encountered the error "TPI Overflow"​. This froze up the pointing check, not letting it progress any further. It was fixed by again restarting and resyncing the DBBC software. Not sure if just    ​* ​ 1700UT - Experiment started OK (Tiege)a one off quirk, but noting it down just in-case. This was all prior to schedule start so no data is affected. (Tiege)+This setup happened after Jamie and Guifre were attempting top upgrade DBBC software. I closed the new DBBC software, opened the old, then restarted fs. Everything was fine (including test recording), however, while doing pointing check (after typing fivept) I encountered the error "TPI Overflow"​. This froze up the pointing check, not letting it progress any further. It was fixed by again restarting and resyncing the DBBC software. Not sure if just a one off quirk, but noting it down just in-case. This was all prior to schedule start so no data is affected. (Tiege
 + 
 +Also, drive information on system monitor for Yg seems to be completely broken. The message box is showing many Monica issues. Have tried restarting both Rxmon and Monica as a whole. This has not fixed it. Telescope appears to be working correctly, I may just need to restart a specific part of Monica that I do not know. (Tiege) 
 + 
 +->Drive info restored after restarting the antmon program [''/​etc/​init.dMonica.antmon stop && /​etc/​init.dMonica.antmon start''​ as root] (JMc
  
    ​* ​ 1700UT - Experiment started OK (Tiege)    ​* ​ 1700UT - Experiment started OK (Tiege)
/home/www/auscope/opswiki/data/attic/handover/r1897.1559575560.txt.gz · Last modified: 2019/06/03 15:26 by Lim Chin Chuan