This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
handover:r1911 [2019/09/09 21:45] Pradyumna Kiran Kummamuru |
handover:r1911 [2019/09/10 10:19] (current) Pradyumna Kiran Kummamuru |
||
---|---|---|---|
Line 9: | Line 9: | ||
* 1700UT - Experiment started OK (Prad). | * 1700UT - Experiment started OK (Prad). | ||
* Unusually delayed response at the FS to commands entered from erc . Hence, just using the oprin window in the vnc viewer. The disk module graphic in the erc is not updating (Prad). | * Unusually delayed response at the FS to commands entered from erc . Hence, just using the oprin window in the vnc viewer. The disk module graphic in the erc is not updating (Prad). | ||
- | * 1919UT - Antenna stuck. Tried 'source=disable', 'antenna=open', switching drives on and off and rebooting central in the HMI, but to no avail. | + | * 1919UT - Antenna stuck at scan# 252-1928b. Tried 'source=disable', 'antenna=open', switching drives on and off and rebooting central in the HMI. The schedule restarted at scan# 252-2154b after attempting the reboot multiple times. (Prad). |
- | * | + | * 2156UT - scan_check reports mk5 data format problem (letter E issue) for scan# 252-2154b. Will require a module swap if the issue persists (Prad). |
+ | * erc displaying wrong DOY and UT. | ||
+ | * 04:52 UT recorded data ahead of scheduled by 112 GB (warren) | ||
+ | * 09:47 UT Waiting at limit for several scans. Field system had forced antenna to limit and would not take new source commands. Restarted the field system and schedule at scan 253-1025a. Scans 253-0953 through 253-1019 not on target (Ross) | ||
{{tag>}} | {{tag>}} |