This shows you the differences between two versions of the page.
| Next revision | Previous revision | ||
|
handover:r1981 [2021/01/11 12:15] Wilson-Mayne |
handover:r1981 [2021/01/11 17:07] (current) Wilson-Mayne |
||
|---|---|---|---|
| Line 4: | Line 4: | ||
| Disk VSN: HOB+1011/16000/1024 | Data volume at beginning: 0 GB | Disk VSN: HOB+1011/16000/1024 | Data volume at beginning: 0 GB | ||
| + | |||
| + | * Error when setting up: SX receiver parameter pres out of range. This indicates that the pressure was too high (~6, should be less that 5. Not a big deal). Alarm ignored as there is nothing we can do about it. (Eloise & Warren) | ||
| - | * 1700UT | + | * 1700UT Experiment started ok (Eloise) |