| + | The latest series of HOB experiments are using X-band for observations on the Hobart12-Hobart26 baseline. To get the best sensitivity we are using the DBBC for Hobart26, rather than the mark4 rack. We use the S/X receiver on the 26m. | ||
| + | |||
| + | ====== Hobart12m ====== | ||
| + | |||
| + | Drudg the experiment file as normal, but please note that you will need to run ''setupxx'' rather than ''setupsx''. Only 8 IFs are being monitored in caltsys (BBCs 1-8, but both USB and LSB channels) and the autocorrelations will appear differently (with the second 8 channels having reversed shapes to the first 8). | ||
| + | |||
| ====== Hobart26m ====== | ====== Hobart26m ====== | ||
| Line 8: | Line 14: | ||
| - ''drudg hob006.skd'' | - ''drudg hob006.skd'' | ||
| - Check equipment with option ''11'' - it should be set to DBBC and Mark5B for the rack and recorder. | - Check equipment with option ''11'' - it should be set to DBBC and Mark5B for the rack and recorder. | ||
| - | - Return to the main menu and produce a proc file with ''12' and snap file with ''3'' | + | - Return to the main menu and produce a proc file with ''12'' and snap file with ''3'' |
| - Copy a previous experiments proc file across to current experiment (these are fairly heavily customised at the moment) with ''cp /usr2/proc/hob005ho.prc /usr2/proc/hob006ho.prc'' | - Copy a previous experiments proc file across to current experiment (these are fairly heavily customised at the moment) with ''cp /usr2/proc/hob005ho.prc /usr2/proc/hob006ho.prc'' | ||
| * On ''hobart'', terminate the FS and then run the following commands: | * On ''hobart'', terminate the FS and then run the following commands: | ||