====== AOV035 ====== **Hobart 26m** Disk VSN: HOB+0125/32000/1024 | Data volume at beginning: 15.9 TB * 1725UT - Cryo monitoring system not working at Ho (ERROR ma -4 Device rx timed-out on response). I have replaced the cryomon and rxmon procedures with nops in EXPERIMENT procedure library for the time being, because otherwise it waits for each rx measurement to time out. I have also commented out the rxmon command in the midob procedure in STATION library, as that is also waiting for timeout, and screwing up scan timing. (Patrick) * 1725UT - ''wx'' command not working. Returning the following errors: (Patrick) * ''wx#Problem connecting to metserver socket'' * ''wx#Illegal error class code: 0xffffffff'' * 1730UT - Experiment started OK (Patrick) * 1842UT - Windstowed from 18:42 - 19:25. (Patrick) * Missed scans: 134-1841b thru 134-1924b * 1925UT - Field system time out of sync (''ERROR sc -13 setcl: formatter to FS time difference 0.5 seconds or greater''). Fixed by running ''sy=run setcl offset'' in oprin. (Patrick) * Also at 20:46, 22:47, 22:52 * 2300UT - Fixed rxmon/cryomon (ERROR ma -4 Device rx timed-out on response) by resetting TTY distributor with "reset" switch on old S/X MarkIV rack. Serial communications from Hobart to s/x receiver are still patched through this rack. (Warren and Brett) * 1200UT- Onsource status is slewing (Momtaz)! **Katherine 12m** Disk VSN:HOB+0015 | Data volume at beginning: 0.0 GB * 1730UT - No system temperature measurements. Restarted DBBC pc, which fixed it. (Patrick) * 1730UT - Experiment started OK (Patrick) **Yarragadee 12m** Disk VSN: HOB+0131 | Data volume at beginning: 0.0 GB * 1730UT - Experiment started OK (Patrick) * 1730UT - no connection to Yg maser (Patrick) {{tag>}} ~~DISCUSSION~~