====== r1650 ====== {{tag>}} ~~DISCUSSION~~ Fringe checks not performed otherwise started on time. Hb: * Frequent error: "Error being ignored: error qk -211 tsys value for device id overflowed or was less than zero." * Bands 07 - 12 high, approximately 130 - 140K. * Recording to BKG+0133. Ke: * power failure caused antenna stuck & missed scans: 238-0301 - 238-0333b, @ 03:00-03:40; clkoff reading was wrong. restart mk5 necessary. * Scans missed/large clkoff: 238-0040b - 238-140b (00:40-01:40 UT). first good scan again: 238-0142 @ 01:42:32 * missed scans occurred after schedule power failure. Generator jumped on, but we got an awkwardly high delay difference. * Tsys in band 09 greater consistently than 190K. * Recording to WSRT-049. Yg: * eRemote connection failed within 5 minutes of starting and on numerous other occasions for up to half an hour. * Frequent warnings : "2014.237.19:37:27 WARNING: error s1 -200 odd response from the pic. aborting...." and "2014.237.19:37:29 WARNING: error s1 -201 ifpcn: error response from ifpic, see s1 -200 error for text." * Recording to OSOD-054.