====== Reprogramming the DBBC ====== Sometimes the DBBC needs reprogramming because channels have been dropped or spectra look strange. To do this, preferable in a gap between scans, follow the following steps: - Open a VNC connection to the DBBC. At Hobart, connect to 131.217.63.248:0 Applications --> Auscope Hobar --> VNC -->dbbchb - You should see a window named ''DBBC2 Control DDC v104_2.exe''. Close it and then restart it from the desktop. When prompted to reconfigure press "y", it takes about 2 minutes. - It is then necessary to make sure the DBBC is synchronised with the station PPS. After some time, in eremotectrl type:dbbc=pps_sync You should then see a row of LEDs on the DBBC flash in sync, once a second. - Lastly, the Mark5 time needs synchronising. To do this, open a terminal on pcfshb and type fmset In the interface, type ''S'' followed by ''y'', then press the **ESC** key. - In the oprin window on pcfshb, type mk5=dot? and check that you see ''syncerr_eq_0'' and ''FHG_on'' (or ''FHG_off''). If you see something like ''syncerr_gt_3'' then ''fmset'' may need to be run again. - Also check that the maser-GPS and delay through the DBBC are the same (to within a microsec) with the ''maserdelay'' and ''clkoff'' commands which read the Agilent counters. - If one or both counters are not responding to these commands, you will see an error message like this ERROR sp -4 GPIB Device time-out on response c2 To fix this, try re-setting the counters. In the ''oprin'' window, type counter and try the ''clkoff'' and ''maserdelay'' commands again.