====== Status after September 2018 visit ====== Read manual, added attenuation to input 10 MHz reduce amplitude to ~-1 dBm rather than 9 dB. Re-tightened internal and external SMA connections - none were loose Removed moderate quantity of bugs from input fan, PSU area. Removed fan and cleaned with compressed air. Voltages Measured at Supply: PC - * GND: Ok. * +5V: 5V. 7mV AC voltage. No ripple, but ~500 mV spikes every ~13 microsec. * +12V: 11.9 V. 1mV AC voltage. No ripple but spikes every ~13-14 microsec. PS1 - Multimeter AC Volts all zero. Ripple present with ~2 MHz frequency. * GND: Ok. * +3.3V (Orange): 3.3V. 600mV p.t.p ripple * +5V (Red): 5V * +12V (Green): 12V 400-500 mV ptp ripple, more regular. * -5V (Violet): -5V PS2 - Multimeter AC Volts all zero. Ripple present with ~2 MHz frequency. * GND: Ok. * +3.3V (Orange): 3.3V . 600mV p.t.p ripple, ~2 MHz period. * +5V (Red): 5V * +12V (Green): +12V * -5V (Violet): -5V