====== Council of Skyence ====== **Chair/Presenting:** Lucas **In Attendance:** Jim, Jamie, Lucia, Liz, Teeg, Jonny, Lucas **Apologies:** **Absent:** Bryn, Jesse, Arwin _______ **Agenda:** - Module at Hobart full or broken, but second module had key switched off - DBBC at Ke been playing up quite a few times over the last fortnight. - Tsys at Yg not working, new hardware on the way to hopefully fix. - Ke cross over switch default setting. Needs attention. - Did you know: new clean page. - Experiment name changed (e.g.) AUA003 instead of 002, make sure cal and master schedule are the same. - Ross-ter to clean kitchen. **Handover notes issues:** - A few problems with *R1780*: - Hb e-remote control didn't work and neither did Dave's backup? Was this resolved and so what was the fix? - Ke DBBC problem? Is that resolved? PCI7200 BOARD. Replaced. - Patrick could you put the problem/fix you had with Ke IF power levels? Also the pointing problem and fix? Ped lost power and tripped E-stop. Needed manual reboot. - Bryn/Tiege, there were MK5 and clock problems at Yarragadee? The fix as per the handover notes seems vague. - *R1782*: - Ross I had the same problem with multiple dim's running. After I logged in as root (su) and tried that seemed to kill them. - Could you please describe how you noticed/diagnosed that the Mark5 disk/Mark5 was faulty at Hb? 'acs problem seems to be related to testing other module.'? Didn't allow recording. Checkmk5 gave an error, scan_check 4/8th line gave a fault message. Swapped to other bank and back then it died. Module marked as bad. - *R4781*: - "IF unit has a fault, probably with the PIC. No noise diode control at the moment, so no Tsys. Power levels into DBBC are OK though. (Jim)'" This was fixed already unless I am mistaken? IF unit works apart from noise diode control, can't measure tsys. New pic on the way. - *R4782*: - Secondary module not correctly inserted into mk5 (I think the key was not turned). When first module became full the the mk5 gave "ERROR m5 -900 : Can't XLRappend() recording" (which is not an alarm) until noticed at 17:00UT. I changed M5 -900 to ALARM in the alarm_actions.txt for Hb. - - If people aren't using Arwins comments.py script, they should be. - Report problems.