**Chair:** Patrick **Attended:** Jonny, Atifur, Mas, Simin, Katie, Tiege, Jamie **Apologies:** Arwin, Ross, Lucas **Absent:** **Handover Issues** * CRF106: * yg: Assigned module (HOB+0107) was full, but used HOB+0097 instead. Module allocation spreadsheet wasn't updated in time. * yg: Eremotectl connection dropped out, caused experiment to start late. Network reliability issue, Brett might take a look at it. * If eremotectl dies, can try restarting ercd daemon on pcfs machine. * If network connection completely drops out call Yg, and they can reboot router from their end. * R1836: * yg: mark5 time 0.2 second off from fs time and computer time, but delays were stable. Experiment already started, didn't want to introduce a clock jump so just left it. Probably due to ntp time small errors, should correct itself. * R4834: * ke: Unlabelled module (StreamStor1) and too dark to verify. Shouldn't be an issue now that Ke interior light fixed **General Issues** * Ke interior light fixed. Can turn on at pdu1ke.phys.utas.edu.au. If stops working, probably bulb burned out, let Mick know (auscopeke mailing address). * Hobart26m drives major failure. Encoder has failed, in repair. Need to do new pointing once it's fixed. Out of action for at least this week. * slogit script is fixed on all machines * Use comments.py or comments.sh? comments.py is best if it works, but shell script is a backup