**Chair:** Katie ** next week's chair: ** Simin **Attended:** Gabor, Lim, Prad, Jay **Apologies:** Tiege, Jamie, Patrick **Absent:** Lucas, Simin, Mas **General Issues** *DBBC software needed a couple of restarts due to the well known TPI overflow issue when doing a pointing check. **Handover Issues** * R1913 * Yg: 1700UT error m5 -900 not whilst recording and error m5 -906 mark5 return code 6: inconsistent or conflicting request seems to happen on every scan.The above error is due to mk5=bank_set? being called during midob. Commented out mk5=bank_set? in midob and moved it to preob. Temporary fix documented here (Lucas) * T2134 * Ho: Something with the wx command. Keep getting 'Problem connecting to metserver socket' and 'illegal error class code' (Prad). * Warren said he would fix. * R1914 * Yg:13:20UT - Network connection between ops8 and pcfsyg down. Can't connect to yg-via-internode. Monitoring, in case it comes back up. Network restored. Contacted Yg and checked everything was operational on their end. Asked them to reboot/power cycle router, but they weren't sure which one (neither was I). Just about to call on-call person, then it came back up.