Oct 20, 2200UT Stuart and Rich not available 6. Follow-up on clock breaks, Maser and A/C moved to different circuits. Ed: R4705had two small breaks at Ho, but no conclusive Brett: sees some jumps when 26m moves Ed: since we aren't recording frequency recording, could a frequency jump be induced to see if it causes a clock jump Brett: let us know when clock jumps occur in experiments Brett: will try looking at power monitor output data for issues Ed: asked Sergei for r4705 break information and will ask analysts to always specify details 7. Final testing of windstow recovery fix. Jim: will finish testing when antenna is up again, by Nov 1. 8. NTP (pcfshb): a. pcfshb needs more stratum 1 servers, especially remote Jim: will look for more stratum 1 servers b. is cnsshb a CNS II clock directly serving NTP or through a TAC32 program? cnsshb is a server, but also used by timehb running TAC32 tac32ho connected to old TAC clock Brett: will make a a diagram c. is tac32ho a TAC32 program connected to a CNS I or a CNS II clock? CNS I d. are there similar issues at other sites and/or 26m? get Hb going first then transfer to other sites - from op comments: 1. FS failure R1708 Hobart26 > R1708: Wrong receiver to start with, FS failure, windstows. Comments by op suggests this is the windstow recovery issue but not sure. Ed: couldn't find FS failure Brett: need to use source=disable to re-connect to antenna rather than restart FS Jim: filter out S/X receiver on axis comments from summary? TBD 2. Hobart26 R1708 had L band selected. > - Receiver stuck in Lband Scans failed 278-1700 through 278-2217 (JS); > 2157UT – OTTER interface reset (using 'r' command) and SX reciever put > on axis (JS) [Have updated the setup notes to include this as a fix for stuck > reciever]; Exactly what is switched between L and SX? RF at the Mark 4 rack via a relay? Brett: moved on axis mechanically, S/X is normally (almost) always connected to rack by cable connection to "normal" (alt may be used for other bands/experiments) 3. R1708 Yg Disc position problem. > R1708: Disc pos ~120 GB behind schedule, inexplicably. Dan suggested this could be caused by disk-record=on is late by the schedule being delayed. Session A1524 Hb, last July it was caused by the weather command sensor but also too many unnecessary checks. Dan can advise on making the Mark5 commands respond faster if requested. Ed: Preob takes 2 second too long Jim: moved azeloff=0d,0d, to sched_initi and removed !*+4s 4. Katherine r4709 (more for Ed’s review) - Field system reboot after start of experiment > Experiment started ok, except the command “clkoff-2” was still in the proc file, > so it recorded a huge delay difference. Halted the schedule after the first scan. > I couldn't find the right file, called Imogen to fix. (Ellen); 18:50 UT – Imogen > was unable to fix due “clkoff-2” to internet problems. I have changed the settings > in the log monitor so it won't ring alarms every scan. Jim: mark5 died, just changed control file for other mark5 and restarted