IMPORTANT INFO for Chris/Anita for Hb
The disk in bank A needs to be changed over tomorrow while Brett is out at Mt. Pleasant and while there is a gap in the schedule.
Hb
Ke
Recording to HOB+0124, start position 5718
GB
Power outage, switched to generator at UT 10:37. Doesn't seem to have affected any scans.
sync error with Mark5B. fmset run at UT 10:58
Antenna stuck. Scans from UT 11:00 to 11:09 affected. Associated scans are: 1739+522, VR422201, 1519-273, 2232-488
3C446 at UT 11:14 is waiting at limit
UT 11:48 Halted schedule. gpib issues –> formatter-mk5 clock problems. Schedule restarted at UT 12:47. First source is 1958-179.
Data from UT 11:00 to 12:53 is probably unusable.
Yg
HartRAO
There was a FS outage at around 07:50 UT and eRCTL collapsed. Jonathan Quick had fixed the problem but just forgot to restart the eRCTL daemon.
eRCTL has intermittent connection. Jonathan Quick sent email about this.