Disk VSN: HOB+0125/32000/1024 | Data volume at beginning: 15.9 TB
1725UT - Cryo monitoring system not working at Ho (ERROR ma -4 Device rx timed-out on response). I have replaced the cryomon and rxmon procedures with nops in EXPERIMENT procedure library for the time being, because otherwise it waits for each rx measurement to time out. I have also commented out the rxmon command in the midob procedure in STATION library, as that is also waiting for timeout, and screwing up scan timing. (Patrick)
1725UT - wx
command not working. Returning the following errors: (Patrick)
1730UT - Experiment started OK (Patrick)
1842UT - Windstowed from 18:42 - 19:25. (Patrick)
1925UT - Field system time out of sync (ERROR sc -13 setcl: formatter to FS time difference 0.5 seconds or greater
). Fixed by running sy=run setcl offset
in oprin. (Patrick)
2300UT - Fixed rxmon/cryomon (ERROR ma -4 Device rx timed-out on response) by resetting TTY distributor with “reset” switch on old S/X MarkIV rack. Serial communications from Hobart to s/x receiver are still patched through this rack. (Warren and Brett)
1200UT- Onsource status is slewing (Momtaz)!
Katherine 12m
Disk VSN:HOB+0015 | Data volume at beginning: 0.0 GB
1730UT - No system temperature measurements. Restarted DBBC pc, which fixed it. (Patrick)
1730UT - Experiment started OK (Patrick)
Yarragadee 12m
Disk VSN: HOB+0131 | Data volume at beginning: 0.0 GB