Hobart:
Katherine:
Yarragadee:
+SUMMARY Qcode % of Total % of Correlated
scans scans
5-9 94% -
0 4% -
4-1,A-H,N 2% - Removed - -
+CORRELATOR_NOTES
+STATION_NOTES
HOBART12 (Hb/d): A few G-codes due to lower signal amplitude in the
last two channels of the S-band.
KATH12M (Ke/a): Missed scans from UT 293-1934 to UT 293-2032, because
FS had to be resynced.
YARRA12M (Yg/i): Ok.
Problems: Several clock breaks at Hobart12. Breaks set at 00:33
(-3.44 nsec) and at 11:52 (-.67 nsec). Also the scans from ~22:23-22:56 on the HB baselines are offset by ~.7 nsec and were deselected. There may be one or two breaks at Yarragadee, but they are not so clear and applying one did not help. The clock constraint was relaxed instead to 6.E-14.
Parameterization comments: None.
Other comments: Hart15m reported bad refraction corrections for
the first 14 hrs, but the data looks okay.
Session Statistics
Observations: 6207 scheduled 6118 correlated (in database) 5588 recoverable (usable) 5350 used Session fit: 36.954 ps
Station Performance
Number of Observations
Scheduled Recoverable* Used % of scheduled obs used
HOBART12 1108 977 918 82.9% KATH12M 1323 1188 1153 87.2% YARRA12M 1163 1045 983 84.5% --------------- --------- ----------- --------- ------ Station Total** 6207 5588 5350 86.2%
MISSED: Station was scheduled, but it did not observe. NOT CORR: Station was scheduled but not correlated. NOT USED: Usable data was generated for this station, but the analyst rejected it all.