Chair: Ross
Attended: Tiege, Lucas, Patrick, Atifur
Apologies: Arwin, Jonny, Simin, Katie, Mas, Jamie, Lucia
Absent:
General Issues
Handover Issues
r4848 (ke) - Can't access maserke vnc, but can ping the machine.
crds96 (ke) - received “Warning: error tc -301 continuous cal not enabled for dbbc” for each scan. Fixed continuous cal not enabled error by changing cont_cal=off to cont_cal=on in the setup01 function of the procedure file, based off the previous crds95 procedure file.
Patrick noticed this the week before. Because experiment drudged manually in the wrong location, it didn't have ke specific procedures.
Version was different to normal, suggesting drudged in a different place.
aov024 (ho) - Was getting “ERROR sc -13 setcl: formatter to FS time difference 0.5 seconds or greater ”. Ran sy=run setcl offset into the newsmerd fs window (oprin)
r1847 (ke) - noticed coordinates had not changed, checked to see the FS had crashed. Restarted FS and the schdule, missing data from 0729 UT till 08:22 UT. It appears log monitor had also stopped responding.
r1847 (yg) - Humidity sensor appears to not be working.
crf107 (ho) - rxp is not providing focus position info, instead it is returning error about connection with remote host lost. Live page says receiver position is correct.
crf107 (ho) - cryomon had negative pressure, likely a bug.
Sound not working on ops8!!
Restarted computer and tried a different set of speakers.
Sound card not working
Use ops4, mobile phone alert and/or byo usb speakers.
What are the ftp links for the vex files, if we can't find the summary files?