1. Resent experiments that were reviewed:

The recent AUSTs experiments are still awaiting correlation and will be reviewed as soon as available. Remasks:

  On the pcfshb VNC session:
      halt
      disk_record=off
      (just to make sure the recorder is stopped)
      antenna=off
      (should turn the drives off, check HMI on timehb)
      terminate
      (This will exit the field system software)
  Then re-start the field system in a terminal with fs. Then in eRemoteCtrl:
      proc=r1653hb
      setupsx
      antenna=open
      antenna=operate
      (check HMI and see if drives power up)
      schedule=r1653hb
      (schedule should start. Wait for next source command and see if antenna slews)

One may also need to open VNC session on timepc and manually switch drived off and on in HMI.

3.