Line 23: | Line 23: | ||
- mk5ke: bank B back plane failure. Affected disks 4/5 and 6/7. Do not use for conditioning. | - mk5ke: bank B back plane failure. Affected disks 4/5 and 6/7. Do not use for conditioning. | ||
+ | - mk5-2ke: module doesn't go all the way in to bank B. | ||
- DBBC: "stuck bit" and bit statistics problems related to VSI OUT connectors: ch15 (S) with VSI1 (rear) -- was problematic from the beginning, ch5 (X) with VSI2 (front) emerged after the inspection and refitting of FILA OUT board. | - DBBC: "stuck bit" and bit statistics problems related to VSI OUT connectors: ch15 (S) with VSI1 (rear) -- was problematic from the beginning, ch5 (X) with VSI2 (front) emerged after the inspection and refitting of FILA OUT board. | ||
- DBBC: suppresses the amplitude of 10-kHz pcal tone (first) in each band. | - DBBC: suppresses the amplitude of 10-kHz pcal tone (first) in each band. | ||
- | |||
- | - Modules: hob+025/6000 has fault in disks 6/7; bkg-0015/1480 took forever to condition. Are labelled as broken and prepared for repair. bkg-0015/1480 should be reprofiled into higher capacity disk. | ||
- Maser: replaced the 'switches' unit and AC/DC converter, cavity tuning and frequency adjustment performed, new standby batteries were installed. | - Maser: replaced the 'switches' unit and AC/DC converter, cavity tuning and frequency adjustment performed, new standby batteries were installed. | ||
+ | |||
+ | **Status:** | ||
+ | |||
+ | - mk5-ke is a main recorder connected to VSI2 on FILA OUT. Channel 5 have a stuck bit. | ||
+ | - 5MHz signal for pcal is connected directly to the second output of the maser through the synch port. | ||
+ | |||
{{tag> backend}} | {{tag> backend}} | ||
Line 58: | Line 63: | ||
- Control room: mk5 light for reading module labels is no longer connected to exterior light switch on ipske. It now switches on ''pdu1ke.phys.utas.edu.au'' and is labelled ''light int'' | - Control room: mk5 light for reading module labels is no longer connected to exterior light switch on ipske. It now switches on ''pdu1ke.phys.utas.edu.au'' and is labelled ''light int'' | ||
+ | |||
+ | - Installed 2 of power distribution units (PDU). These are like an 8 way power board that have individually switched outputs. They can be switched from a web interface at the following 2 links: | ||
+ | \\ [[http://pdu1ke.phys.utas.edu.au/outlet.htm|pdu1ke.phys.utas.edu.au/outlet.htm]] | ||
+ | \\ [[http://pdu2ke.phys.utas.edu.au/outlet.htm|pdu2ke.phys.utas.edu.au/outlet.htm]] | ||
+ | |||
+ | The user is admin and the password is the same one we use for the internet power switches. | ||
+ | \\ PDU1KE so far has wifi, cduke (network maint computer) and the interior light. | ||
+ | \\ PDU2KE so far has mk5-2ke and the GPIB controller. | ||