blog:dbbc_power_modules [2013/09/11 06:17]
Brett Reid
blog:dbbc_power_modules [2013/09/23 08:27] (current)
Moblas people
Line 7: Line 7:
  
 ~~DISCUSSION~~ ~~DISCUSSION~~
-Measured supply voltage and ripple on the 2 Lambda power modules in base of Hobart12 DBBC. +Measured supply voltage and ripple on the 2 Lambda power modules in base of Hobart12 DBBC. \\ 
-Module 1 +Module 1 \\ 
-3.3V = 3.284V with 40mV  P-P ripple +3.3V = 3.284V with 40mV  P-P ripple ​\\ 
-5V   = 5.02V  with 60mV  P-P ripple +5V   = 5.02V  with 60mV  P-P ripple ​\\ 
-12V  = 12.01V with 130mV P-P ripple +12V  = 12.01V with 130mV P-P ripple ​\\ 
--5V  = -5.03V with 100mV P-P ripple+-5V  = -5.03V with 100mV P-P ripple ​\\ 
 +\\ 
 +Module 2 \\ 
 +3.3V = 3.293V with 32mV  P-P ripple \\ 
 +5V   = 5.03V  with 84mV  P-P ripple \\ 
 +12V  = 11.94V with 135mV P-P ripple \\ 
 +-5V  = 5.03V  with 70mV  P-P ripple \\ 
 +\\ 
 +Measured supply voltage and ripple on the 2 Lambda power modules in base of Yarragadee DBBC. \\ 
 +23/9/2013 \\ 
 +Module 1 \\ 
 +3.3V = 3.316V with 60mV  P-P ripple \\ 
 +5V   = 5.012V with 90mV  P-P ripple \\ 
 +12V  = 12.15V with 150mV P-P ripple \\ 
 +-5V  = -5.01V with 100mV P-P ripple \\ 
 +\\ 
 +Module 2 \\ 
 +3.3V = 3.315V with 60mV  P-P ripple \\ 
 +5V   = 5.014V with 100mV P-P ripple \\ 
 +12V  = 12.29V with 170mV P-P ripple \\ 
 +-5V  = 5.02V  with 80mV  P-P ripple \\
  
-Module 2 
-3.3V = 3.293V with 32mV  P-P ripple 
-5V   = 5.03V  with 84mV  P-P ripple 
-12V  = 11.94V with 135mV P-P ripple 
--5V  = 5.03V  with 70mV  P-P ripple ​ 