User Tools

Site Tools


deformation:testsetup1

This wiki is not maintained! Do not use this when setting up AuScope experiments!

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
deformation:testsetup1 [2012/08/29 03:22]
Jim Lovell created
deformation:testsetup1 [2012/11/29 05:19]
Jim Lovell [PC Software]
Line 16: Line 16:
   * From the LoggerNet CD   * From the LoggerNet CD
     * Installed the software (key printed on CD)     * Installed the software (key printed on CD)
-    ​+ 
 +  ​Ran LoggerNet and started through setup wizard 
 +    * Selected CR1000, named it Array 1 
 +    * Selected IP Port as Communication Setup 
 +    * Now need to give it an IP address... 
 +      * Will configure over serial connection 
 +      * USB to serial connector required driver from manufacturer:​ 
 +        * Manual at at http://​sabrent.com/​product-manuals/​USB-TO-SERIAL-CABLES_Manual.pdf 
 +        * Want driver for SBT-USC6K from http://​www.sabrent.com/​downloads.php 
 +        * Followed installation instructions 
 +        * Came up on COM3, 9600 baud, 8 bit, parity none, stop bits 1, flow control none. 
 +      * Connected power to logger via DC power-pack. No luck. Direct connection to battery works 
 +      * MAC address for Array 1 00d02c04b057,​ Array 2 00d02c04b051 and temporary IP addresses are 131.217.62.92 and .93 respectively and called AUScope-Array1.phys... and AUScope-Array2.phys... 
 +      * In Device Config Utility,  
 +        * Connection over serial with ethernet plugged in, shown DHCP working and TCP port set to 6785 
 +        * In Datalogger tab, Station name is Array1, PakBus Address 1, security code 0 
 +        * edited .cipasswd file (New Services Tab) to give usual observer password for admin, FTP password for anonymous is the same 
 +        * In logger Control, hit Set clock (synchs with PC clock, so that needs to be on an NTP server) 
 +        * In data monitor, can see logged data (after plugging in sensors), other stats like batther level etc. 
 +        * Finished, so disconnect. 
 +      * Now in EZSetup Wizzard 
 +        *  IP address set to 131.217.62.92:​6785,​ pakbus 1, security code 0 
 +        * Comm test worked! 
 +      * Configured Array2 as above, just different name and I address, PakBus Address 1 (tried 2 but failed the comms test).