User Tools

Site Tools


handover:a1516

This wiki is not maintained! Do not use this when setting up AuScope experiments!

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Last revision Both sides next revision
handover:a1516 [2015/06/03 01:08]
Jim Lovell
handover:a1516 [2015/06/03 12:43]
Jim Lovell
Line 7: Line 7:
 Data volume at beginning: 18158.799 GB Data volume at beginning: 18158.799 GB
  
-       * I have been restarting rxmon everytime it has an error and the disc pos deficit is still increasing, currently ~60 GB. (Ellen)+       ​* ​01:04 UT - I have been restarting rxmon everytime it has an error and the disc pos deficit is still increasing, currently ~60 GB. (Ellen
 +       * 03:03 UT - Disc pos ~80 GB behind. (Ellen) 
 +       * 05:52 UT - Disc pos ~110 GB behind. (Ellen) 
 +       * 12:40 UT - Disc pos ~150 GB behind. (Dave)
  
  
Line 24: Line 27:
  
       * 00:43 UT - During scans 154-0043 and 0044 got the following errors: WARNING: error an -103 pointing computer tracking errors are too large ;  WARNING: error qo -301 warning: onsource status is slewing! Scans probably bad. (Ellen)       * 00:43 UT - During scans 154-0043 and 0044 got the following errors: WARNING: error an -103 pointing computer tracking errors are too large ;  WARNING: error qo -301 warning: onsource status is slewing! Scans probably bad. (Ellen)
 +      * Tsys bands 13, 14 consistently quite high. (Ellen)
 +      * 0919 UT - S-band IF attenuators were at 10 db and AGC in ifc was overflowing. Ran ifnom to increase attenuation to 15 db in S band. (Dave)
  
 {{tag>}} {{tag>}}
/home/www/auscope/opswiki/data/pages/handover/a1516.txt · Last modified: 2015/06/03 14:45 by liza